提交詢(xún)價(jià)信息 |
發(fā)布緊急求購(gòu) |
價(jià)格:電議
所在地:湖北 武漢市
型號(hào):NASGQ
更新時(shí)間:2024-02-28
瀏覽次數(shù):1345
公司地址:中國(guó)大陸及國(guó)外
陳茜茜(女士) 專(zhuān)員
NASGQ Series Digital Display Clamp-on Phase Meter
南澳電氣NASGQ數(shù)字雙鉗相位伏安表
產(chǎn)品簡(jiǎn)介
南澳電氣NASGQ數(shù)字雙鉗相位伏安表是專(zhuān)為現(xiàn)場(chǎng)測(cè)量電壓、電流及相位而設(shè)計(jì)的一種、位、手持式、雙通道輸入測(cè)量?jī)x表。NASGQ數(shù)字雙鉗相位伏安表可以很方便地在現(xiàn)場(chǎng)測(cè)量U-U、I-I及U-I之間的相位,判別感性、容性電路及三相電壓的相序,檢測(cè)變壓器的接線組別,測(cè)試二次回路和母差保護(hù)系統(tǒng),讀出差動(dòng)保護(hù)各組CT之間的相位關(guān)系,檢查電度表的接線正確與否等。采用鉗形電流互感器轉(zhuǎn)換方式輸入被測(cè)電流,因而測(cè)量時(shí)無(wú)需斷開(kāi)被測(cè)線路。測(cè)量U1-U2之間相位時(shí),兩輸入回路完全緣隔離,因此完全避免了可能出現(xiàn)的誤接線造成的被測(cè)線路短路、以致燒毀測(cè)量?jī)x表。顯示器采用了高反差液晶顯示屏,字高達(dá)25mm,屏幕角度可自由轉(zhuǎn)換約70°,以獲得視覺(jué)效果。
南澳電氣NASGQ數(shù)字雙鉗相位伏安表外殼采用工程緣材料,另配橡皮防振保護(hù)套,安全、可靠。
南澳電氣NASGQ數(shù)字雙鉗相位伏安表產(chǎn)品別名
相位表,,雙鉗相位伏安表,鉗形相位表,鉗形相位伏安表,數(shù)字雙鉗相位表,數(shù)字式雙鉗相位表,低壓伏安相位檢測(cè)表,手持式數(shù)字雙鉗相位伏安表,雙鉗式數(shù)字相位表,雙鉗數(shù)字式相位表,雙鉗式伏安相位表,雙鉗伏安相位表,數(shù)顯雙鉗相位表
南澳電氣NASGQ數(shù)字雙鉗相位伏安表產(chǎn)品特性
1、不需拆母線, 一鍵全自動(dòng)測(cè)量, 精度高, 穩(wěn)定性好, 技術(shù)
2、量程自動(dòng)轉(zhuǎn)換, 大屏幕液晶顯示, 漢字菜單操作提示, 可儲(chǔ)存和打印數(shù)據(jù)
1、工作條件
1、環(huán)境溫度:(23±5)℃
2、環(huán)境濕度:(45~75)% RH
3、被測(cè)信號(hào)波形:正弦波、β=0.02
4、被測(cè)信號(hào)頻率:(50±0.2)Hz
5、被測(cè)載流導(dǎo)線在鉗口中的位置:任意
6、測(cè)量相位時(shí)被測(cè)信號(hào)幅值范圍:100~220V、0.~1.5
7、外參比頻率電磁場(chǎng)干擾:應(yīng)避免
2、 基本誤差限
項(xiàng) 目 |
NASGQB |
NASGQE |
|||||
交流電壓測(cè)量誤差 |
量 限 |
20V |
200V |
500V |
20V |
200V |
500V |
分 辨 率 |
0.01 |
0.1 |
1 |
0.01 |
0.1 |
1 |
|
基本誤差限 |
±(1.2%RD+2) |
±(1.0%RD+2) |
±(1.2%RD+2) |
±(0.3%讀數(shù)+0.2%量程) |
|||
輸入阻抗 |
各量限均為2MΩ |
各量限均為2MΩ相位測(cè)量時(shí),電壓端輸入阻抗>500KΩ |
|||||
交流電流測(cè)量誤差 |
量 限 |
200mA |
2A |
10A |
200mA |
2A |
10A |
分 辨 率 |
0.1mA |
1mA |
10mA |
0.1mA |
1mA |
10mA |
|
基本誤差限 |
±(1.0%RD+2) |
±(0.3%讀數(shù)+0.2%量程) |
|||||
工頻相位測(cè)量誤差 |
范 圍 |
0~360° |
|||||
分辨率 |
1° |
||||||
基本誤差限 |
±3° |
±2° |
工作誤差
1、額定工作條件
1、環(huán)境溫度:(0~40)℃
2、環(huán)境濕度:(20~80)% RH
3、被測(cè)信號(hào)波形:正弦波、β=0.05
4、被測(cè)信號(hào)頻率:(50±0.5)Hz
5、被測(cè)載流導(dǎo)線在鉗口中的位置:任意
6、測(cè)量相位時(shí)被測(cè)信號(hào)幅值范圍
測(cè)U1-U2相位時(shí):30V~500V
測(cè)I1-I2 相位時(shí):10mA~10.00A
測(cè)U1-I2 或 I1-U2 相位時(shí):10V~500V、10mA~10.00A
7、外參比頻率電磁場(chǎng)干擾:應(yīng)避免
2、額定工作誤差限
在1 所述額定工作條件下,各被測(cè)量的額定工作誤差限不超過(guò)相應(yīng)基本誤差限的兩倍。
其它技術(shù)特性
1、顯示位數(shù):三位半
2、采樣速率:3次/秒
3、電源:?jiǎn)蝹€(gè) 9V 迭層電池、電源電流小于5mA
4、重量
表體:280g
測(cè)量鉗:2×200g
Product introduction
NASGQ series Digital Display Clamp-on Phase Meter is special designed for voltage, current and phase tests, it is in high-precision, low price, portable hand-held, dual-channel input measuring. It's easy to measure the phase between U-U, I-I and U-I, identify the inductive circuit ,capacitive circuit and the phase sequence of three-phase voltage, detect the wiring group of transformer, test the seco
The shell of the device is made of engineering insulating material, together with a rubber–made anti-vibration protection kits for safety and reliability.
Also called name
Phase meter, clamp phase meter, digital clamp phase meter
The Characteristics of the products
1. Withstand Voltage
Parts between voltage input terminal and meter shell, parts between the iron core of the clamp-current transformer and seco
2. Insulation Resistance
Between meter circuit and meter shell, between the two voltage input terminals:≥10MΩ
The parameters of the products
1. Intrinsic Error
1.1 Reference Operating Co
(1) Temperature: (23±5)℃
(2) Humidity: (45~75)% RH
(3) Wave forms of measured signal: sine wave β=0.02
(4) Frequency of measured signal: (50±0.2)Hz
(5) Position of Measured current carrying co
(6) Amplitude range of measured signal when measuring phase: 100~220V, 0.~1.
(7) External reference frequency electromagnetic interference: Should be avoided
1.2 The limits of intrinsic error
project |
NASGQB |
NASGQE |
|||||
Error of AC Voltage |
Measure range |
20V |
200V |
500V |
20V |
200V |
500V |
Resolution |
0.01 |
0.1 |
1 |
0.01 |
0.1 |
1 |
|
Intrinsic limits of error |
±(1.2%RD+2) |
±(1.0%RD+2) |
±(1.2%RD+2) |
±(0.3%RD+0.2% Range) |
|||
Input Impedance |
All the measure range is 2MΩ |
All the measure range is 2MΩ Voltage input impedance of phase testing: >500KΩ |
|||||
Error of AC Current |
Measure range |
200mA |
2A |
10A |
200mA |
2A |
10A |
Resolution |
0.1mA |
1mA |
10mA |
0.1mA |
1mA |
10mA |
|
limits of intrinsic error |
±(1.0%RD+2) |
±(0.3% RD +0.2% Range) |
|||||
Error of Power-frequency Phase |
Range |
0~360° |
|||||
Resolution |
1° |
||||||
limits of intrinsic error |
±3° |
±2° |
2. Operating error
2.1 Rated Operating Co
(1) Temperature (0~40)℃
(2) Humidity: (20~80)% RH
(3) Wave forms of measured signal: sine wave β=0.05
(4) Frequency of measured signal: (50±0.5)Hz
(5) Position of Measured current carrying co
(6) Amplitude range of measured signal when measuring phase,
Phase U1-U2: 30V~500V
Phase I1-I2: 10mA~10.00A
Phase U1-I2 or I1-U2: 10V~500V, 10mA~10.00A
(7) External reference frequency electromagnetic interference: should be avoided
2.2 Limits of rated operating error
Under the co
3. Other technical parameters:
(1) Display: three and half digital
(2) Sampling rate: 3 times/ seco
(3) Power supply: single laminated batteries with 9V, the current of power supply is less than 5 mA.
(4)Dimension:
The size of the shell of meter: 192mm×95mm×55mm
The size of the shell of clamp: 140mm×42mm×20mm
The size of jaws: Φ7mm×9mm
(5)Weight:
The weight of meter: 280g
The weight of clamp: 2×200g
(6)the co
Temperature: -10℃~ 50℃